Compartir
Fabrication and Cold-Flow Testing of Subscale Space-Based Laser Geometry (en Inglés)
Scott E. Bergren
(Autor)
·
Biblioscholar
· Tapa Blanda
Fabrication and Cold-Flow Testing of Subscale Space-Based Laser Geometry (en Inglés) - Bergren, Scott E.
S/ 255,37
S/ 510,75
Ahorras: S/ 255,37
Elige la lista en la que quieres agregar tu producto o crea una nueva lista
✓ Producto agregado correctamente a la lista de deseos.
Ir a Mis Listas
Origen: Estados Unidos
(Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el
Viernes 26 de Julio y el
Martes 06 de Agosto.
Lo recibirás en cualquier lugar de Perú entre 2 y 5 días hábiles luego del envío.
Reseña del libro "Fabrication and Cold-Flow Testing of Subscale Space-Based Laser Geometry (en Inglés)"
The objectives of this research were to build a facility that could simulate the expected fluid flow properties in the conceptual Space Based Laser Integrated Flight Experiment (SBL IFX) gas dynamic laser using cold-flow, and to investigate the performance of the model. A 1/5-scale model of one quadrant of the SBL IFX cylindrical, gas dynamic laser was fabricated and mated to a blow-down/vacuum combination wind tunnel. The primary components of the test apparatus consisted of a nozzle array, optical cavity, supersonic diffuser, centerbody, and transition. The throat height of a single nozzle was 1 mm and the expansion ratio was two. The transition structure was designed to attach the subscale model to the wind tunnel facility vacuum line and was not part of the SBL IFX design. Using rapid data acquisition and schlieren photography, the fluid velocities in the diffuser where determined to became subsonic after a transient time interval of 0.2 seconds from wind tunnel startup for a 30 second long test. During this transient time interval, a well-defined, attached oblique shock wave was observed off the leading edge of the centerbody within the optical cavity of the diffuser, and the fluid in the optical cavity reached an observed maximum Mach number of 2.7. The brevity of the supersonic flow within the optical cavity was due to the minimum area of the transition structure being too small to swallow a normal shock that propagates down the length of the test section during a transient time period at wind tunnel startup.
- 0% (0)
- 0% (0)
- 0% (0)
- 0% (0)
- 0% (0)
Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.
✓ Producto agregado correctamente al carro, Ir a Pagar.